Description
1. More convenient, easy to get access to the status of the inverters.
2. The control of the inverter can be conducted in any places you like, just a more comfortable way of life.
3. 12v/24v auto-adaptive feature makes the inverter more compatible. Just one inverter, two battery models can be conncted. Save money and more choices for you.
4. High Quality, CE and RoHS guaranteed, very low no-load current, high conversion efficiency up tp 88%, 90% and 92%.
5. It runs with full power, with the peak power double the continuous output.
6. Six protect function: low voltage protection, over voltage protection, over load protection, over temperature protection, short circuit protection and input reverse polarity protection. Just give you a safe, secure power-using environment. With it, you can rest assure that you and your life are protected by it.
7. Intelliegent cooling system is also for you to use it in a safe environment.
8. Various socket types for you to select to match your nation’s wall outlet or plug.
Model | M-500W-12V | M-500W-24V | M-500W-48V |
Output Power | 500W | ||
Peak Power | 1000W | ||
DC Input Voltage Range | DC12V(9.5V-15.5V) | DC24V(19V-31V) | DC48V(38V-62V) |
AC Output Voltage (Single Choice) | 100V/110V/120V/220V/230V/240V | ||
Unload Current | ≤0.5A | ≤0.3A | ≤0.2A |
Output Frequency | (50Hz±2Hz) or( 60Hz±2Hz) | ||
Output Waveform | Modified sine wave | ||
Display | / | ||
USB Output Votlage / Current | 5V 2A (Support QC3.0 fast charge up to 18W) | ||
Max. Output Efficiency | 88% | 90% | 92% |
Low Voltage Protection | Alarm “Bi” with 2s interval +red and green lights flashing alternately / restart automatically when voltage recover | ||
Over Voltage Protection | Alarm “BiBi” with 1s interval +red and green lights flashing alternately / restart automatically when voltage recover | ||
Over Load Protection | Alarm “Bi” continously +red light flashing / restart automatically when load power recover; If it is closed after twice recover, it need restart manually. | ||
Over Temp Protection | Alarm “BiBiBi” with 1s interval +red and green lights flashing alternately / restart when temp recover | ||
Short Circuit Protection | yes | ||
DC Reverse Connection Protection | Fuse burnt | ||
Low Voltage Alarm Range | 10.5v±0.5v | 21v±0.5v | 42v±0.5v |
Low Voltage Protection Range | 9.5v±0.5v | 19v±0.5v | 38v±0.5v |
Low Voltage Recover Range | 12v±0.5v | 23v±0.5v | 46v±0.5v |
Over Voltage Protection Range | 15.5v±0.5v | 31v±0.5v | 62v±0.5v |
Over Voltage Recover Range | 14v±0.5v | 28v±0.5v | 56v±0.5v |
Working Temperature | -10℃~50℃ | ||
Cooling Method | Fan cooling (Temperature control) | ||