Description
Product Features
Technical Parameters
Document Download
Product Features
1. LED indicates load status
2. Soft start, effectively maintain battery life
3. Overload/short circuit protection
4. Overvoltage/undervoltage protection
5. OEM and ODM are available, and the shell color can be customized.
6. High Inrush: High inrush current capability to start difficult loads.
7. Grounding protection: There are terminals on the front panel to ground the inverter.
8. The cooling fan in the inverter is thermally activated, starts when the inverter gets hot, and turns off automatically when the inverter cools down.
Technical Parameters
Model | M-1500W-12V | M-1500W-24V | M-1500W-48V |
Output Power | 1500W | ||
Peak Power | 3000W | ||
DC Input Voltage Range | DC12V(9.5V-15.5V) | DC24V(19V-31V) | DC48V(38V-62V) |
AC Output Voltage (Single Choice) | 100V/110V/120V/220V/230V/240V | ||
Unload Current | ≤0.5A | ≤0.3A | ≤0.2A |
Output Frequency | (50Hz±2Hz) or( 60Hz±2Hz) | ||
Output Waveform | Modified sine wave | ||
Display | LED or LCD display | ||
USB Output Votlage / Current | 5V 2A (Support QC3.0 fast charge up to 18W) | ||
Max. Output Efficiency | 88% | 90% | 92% |
Low Voltage Protection | Alarm “Bi” with 2s interval +red and green lights flashing alternately / restart automatically when voltage recover | ||
Over Voltage Protection | Alarm “BiBi” with 1s interval +red and green lights flashing alternately / restart automatically when voltage recover | ||
Over Load Protection | Alarm “Bi” continously +red light flashing / restart automatically when load power recover; If it is closed after twice recover, it need restart manually. | ||
Over Temp Protection | Alarm “BiBiBi” with 1s interval +red and green lights flashing alternately / restart when temp recover | ||
Short Circuit Protection | yes | ||
DC Reverse Connection Protection | Fuse burnt | ||
Low Voltage Alarm Range | 10.5v±0.5v | 21v±0.5v | 42v±0.5v |
Low Voltage Protection Range | 9.5v±0.5v | 19v±0.5v | 38v±0.5v |
Low Voltage Recover Range | 12v±0.5v | 23v±0.5v | 46v±0.5v |
Over Voltage Protection Range | 15.5v±0.5v | 31v±0.5v | 62v±0.5v |
Over Voltage Recover Range | 14v±0.5v | 28v±0.5v | 56v±0.5v |
Working Temperature | -10℃~50℃ | ||
Cooling Method | Fan cooling (Temperature control) | ||
Note: The tech updates constantly. These datas are used for reference only. Please refer to our real product. |